输出电压OUTPUT(V)
|
6----11
|
11.1----15
|
15.1----22
|
22.1----30
|
30.1----60
|
输出电流OUTPUT(A)
|
0.01----8
|
0.01----7
|
0.01----6.5
|
0.01----4
|
0.01----4.2
|
输出功率OUTPUT(W)Max
|
85
|
90
|
90
|
100
|
120
|
输入INPUT
|
电压Voltage/频率Hz
|
100V—240VAC 50-60Hz
|
调整范围Adjusting range
|
90V—264VAC,47Hz—63Hz
|
电流Current
|
3A Max
|
保护Protection
|
内置一次性保险丝不可拆卸Internal Primary Current Fuse, Inrush Limiting
|
输出 OUTPUT
|
负载调整率Load regulation
|
±5%
|
额定/瞬间功率 Rated power/Max power
|
120W/150W
|
纹波Ripple
|
<200mV
|
瞬态响应Transient Response
|
在50%负载时0.5毫秒 0.5mS for 50% Load Change Typical
|
过流保护点OCP
|
105%~150%
|
保护Protection
|
短路保护/过载保护/过温保护,可自动恢复.
Short Circuit protection/Over voltege protection/Over Temperature protection,
Can automatically recover.
|
电性 Electrical
|
绝缘强度Dielectric Withstand
|
4242 VDC Primary – Secondary
|
漏电流Leakage Current
|
0.25mA @ 2 Pin / 0.5mA @ 3 Pin
|
转换效率 Efficiency
|
符合5级能效及ERP阶段2认证 Engergy Star Level V & ErP Stage 2 Certified
|
EMI传导和辐射EMI Conduction & Radiation
|
EN:55022:2010,EN55014-1,EN61000-3-3:2013
|
浪涌电流 surge current
|
当输出为额定负载,环境温度为25℃,输入240VAC冷态起动电源时的最大浪涌电流小于30A,30A MPS@240VAC at 25 ℃ Cold start
|
抗静电EMS Immunity
|
IEC61000-4-2
|
绝缘等级Insulation class
|
输入对地最小50兆欧 50M ohms minimum from input to ground
|
平均无故障时间 MTBF
|
在25℃环境温度下,额定负载工作平均无故障时间30,000小时;In 25 environment Temp,The Rated load MTBF 30000H
|
使用环境Environmental
|
工作温度Operaturing Temperature
|
0 to +40°C
|
储存温度Storage Temperature
|
-20 to +80°C
|
相对湿度Relative Humidity
|
工作:20%~80%RH Operating 20 to 80% RH
|
储存:10 - 90% RH Storage: 10 to 90% RH
|
冷却方式Cooling
|
自然冷却Natural Convection Cooling
|
安规认证Safety Approvals
|
CCC TUV-CE-EMC TUV-CE-LVD TUV-GS TUV-FCC SAA(RMC) TUV-PSE TUV-CB CUL UL ROHS
|
尺寸SIZE
|
|